Current evidence on intermittent catheterization: sterile single-use catheters or clean reused catheters and the incidence of UTI

J Wound Ostomy Continence Nurs. 2007 May-Jun;34(3):289-96. doi: 10.1097/01.WON.0000270824.37436.f6.

Abstract

Purpose: Intermittent catheterization is a commonly prescribed procedure for people with incomplete bladder emptying not managed by other methods. The most frequent complication of intermittent catheterization is urinary tract infection (UTI). It is unclear what strategies, including sterile vs clean catheters or coated vs uncoated PVC catheters, affect the incidence of UTIs. This systematic review summarizes current evidence on the relationship between sterile single-use catheters or clean reused catheters and the incidence of UTIs.

Search strategy: The Cochrane Incontinence Group trials register, Medline, EMBASE, CINAHL, and ERIC were searched, plus the reference lists of relevant articles and conference proceedings. Randomized controlled trials comparing at least two different products or methods for intermittent catheterization were included.

Data collection and analysis: Three reviewers assessed the methodological quality of trials and abstracted data.

Main results: Of the 13 trials that met the inclusion criteria on intermittent catheterization protocols, there was considerable variation in length of follow-up, definitions of UTI, and numbers of subjects. Attrition was a problem for several studies, and all were underpowered. Several studies were more than 10 years old, and outcome measures were imprecise, making it difficult to draw conclusions on the benefit of one catheterization method over another.

Conclusions: There are no definitive studies illustrating that incidence of UTIs is affected by sterile single-use or coated catheters compared to clean reused catheters. However the current research base is weak and design issues are significant. Based on the current data, it is not possible to state that one catheter method is better than another and further research on the topic is strongly recommended.

Publication types

  • Review
  • Systematic Review

MeSH terms

  • Clinical Nursing Research
  • Coated Materials, Biocompatible / adverse effects
  • Coated Materials, Biocompatible / therapeutic use
  • Disposable Equipment* / statistics & numerical data
  • Equipment Contamination
  • Equipment Reuse*
  • Evidence-Based Medicine*
  • Health Services Needs and Demand
  • Humans
  • Incidence
  • Infection Control / methods
  • Infection Control / standards
  • Outcome Assessment, Health Care
  • Randomized Controlled Trials as Topic
  • Research Design
  • Urinary Catheterization* / adverse effects
  • Urinary Catheterization* / instrumentation
  • Urinary Catheterization* / methods
  • Urinary Tract Infections / epidemiology*
  • Urinary Tract Infections / etiology
  • Urinary Tract Infections / prevention & control

Substances

  • Coated Materials, Biocompatible