Evid Based Nurs 6:22 doi:10.1136/ebn.6.1.22
  • Assessment (screening or diagnosis)

Doppler echocardiography was not accurate for diagnosing asymptomatic thrombosis associated with an umbilical venous catheter in infants

 QUESTION: What is the accuracy of Doppler echocardiography for diagnosing asymptomatic thrombosis associated with an indwelling umbilical venous catheter (UVC) in infants?


Blinded comparison of Doppler echocardiography with contrast venography.


A neonatal intensive care unit (NICU) at a university based hospital in Hamilton, Ontario, Canada.


47 infants (mean gestational age 32.2 wks, mean birth weight 1962 g, 51% boys) who had in situ UVCs for ≥48 hours and the catheter was scheduled for elective removal. All catheters had single lumens and were made of polyvinyl chloride; heparin was not added to intravenous solutions and no blood products were given through the UVC. Exclusion criteria were symptoms and signs of catheter associated thrombosis or catheter malfunction; known anatomic defects of the heart and great vessels; failure to position the tip of the catheter just above the diaphragm, in either …

Free Sample

This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of EBN.